燃?xì)忮仩t不只愈加清潔環(huán)保,燃料應(yīng)用率和效能也比其他燃料類型的鍋爐高出很多,普遍掩蓋在我國(guó)各行各業(yè)的工業(yè)加工消費(fèi)上,在化工消費(fèi)、食品加工、紡織、造紙等多個(gè)行業(yè)均有運(yùn)用。很多運(yùn)用燃?xì)忮仩t的用戶向我們反映,在剛啟動(dòng)鍋爐時(shí),會(huì)呈現(xiàn)點(diǎn)不著火的狀況。燃?xì)忮仩t遇到這種狀況主要是熄滅器零部件和氣壓的問(wèn)題,依據(jù)不同狀況,可做如下剖析。
Gas-fired boilers are not only cleaner and more environmentally friendly, but also have higher fuel utilization rate and efficiency than other types of boilers. They are generally concealed in the industrial processing consumption of all walks of life in our country, and are used in many industries, such as chemical consumption, food processing, textile, paper making and so on. Many users who use gas-fired boilers tell us that when the boiler is just started, it will not ignite at all. Gas-fired boilers encounter this situation mainly because of the problems of extinguisher components and air pressure. According to different conditions, the following analysis can be made.
一、啟動(dòng)后前吹掃正常,但點(diǎn)不著火
1. Cleaning is normal before and after start-up, but it does not ignite.
1、電火氣量缺乏:檢查線路并修復(fù)
1. Lack of Electric-Fire Gas: Check Circuits and Repair
2、電磁閥燒壞、不工作(主閥、點(diǎn)火閥):換新
2. Solenoid Valve Burn out, Not Working (Main Valve, Ignition Valve): Renovation
3、氣壓不穩(wěn)定:調(diào)整氣壓至規(guī)則值
3. Air pressure instability: adjust air pressure to regular value
4、風(fēng)量太大:減小配風(fēng),減小風(fēng)門開(kāi)度
4. The air volume is too large: reduce the air distribution and the opening of the throttle
二、鍋爐氣壓正常,點(diǎn)不著火
2. The pressure of the boiler is normal and it will not ignite.
1、點(diǎn)火變壓器燒壞:換新
1. Burning out of ignition transformer: renewal

2、高壓線損壞或零落:重新裝置或換
2. High Voltage Wire Damage or Fragmentation: Re-installation or Replacement
3、點(diǎn)火棒位置相對(duì)尺寸間隙過(guò)大或過(guò)?。褐匦抡{(diào)整
3. Ignition rod position relative size gap is too large or too small: readjustment
4、電極決裂或與地短路:重新裝置或換新
4. Electrode Cracking or Ground Short Circuiting: Re-installation or Renovation
5、間距不適宜:重新調(diào)整
5. Inappropriate spacing: readjustment
三、鍋爐點(diǎn)著后5~6秒后熄火
3. Flameout after 5-6 seconds of boiler ignition
1、氣壓缺乏,壓降太大,供氣流量偏?。褐匦抡{(diào)整氣壓,清算濾網(wǎng)
1. Lack of air pressure, too large pressure drop and too small supply air flow: readjusting air pressure and clearing filter screen
2、風(fēng)量太小,熄滅不充沛,煙色較濃 :重新調(diào)整
2. The air volume is too small, the extinguishment is not sufficient, and the smoke is strong: readjustment
3、風(fēng)量太大,呈現(xiàn)白氣:重新調(diào)整
3. Too much air, showing white air: readjustment
The wonderful content of this article is provided by Shandong Gas Boiler Manufacturer. There are many wonderful contents on this website. You can click on more content to enter: http://m.tiaoi.com.cn! We have a special customer service to answer your questions.